All functions on the the Guardian 1030S, including the internal 8 channel scanner, can be programmed via front panel or remotely via RS-232. The Guardian 1030S can perform AC Hipot tests over a programmable voltage range from 50 to 5000 V, with leakage current detection from 1 μA to 30 mA; DC Hipot tests over a programmable voltage range from 50 to 6000 V, with leakage current detection from 0.1 μA to 10 mA; insulation resistance (IR) measurements over the range of 100 kΩ to 50 GΩ with a programmable test voltage from 50 to 1000 VDC.